IDENTIFIKASI KENYAMANAN TERMAL RUANG PADA RUMAH BETANG ENSAID PANJANG DI KABUPATEN SINTANG
DOI:
https://doi.org/10.26418/jmars.v10i2.55797Keywords:
Traditional Architecture, Traditional Houses, Thermal Comfort, Building ComfortAbstract
Traditional architecture is an architectural form that passed down from one generation to the next. Traditional houses are formed through a long time that are responsive to the environment. The traditional houses adapt with the environment to increase their level of comfort and reduce disturbances for a comfortable living. This study aimed to identify the thermal comfort of Betang Ensaid Panjang, which is the traditional Dayak houses in Sintang Regency. Identification of the thermal comfort was done by measuring the influential thermal variables; air temperature, humidity, wind speed, the clothing insulation and the metabolism at Betang Ensaid Panjang. As a building that located in a tropical climate, an analysis of the tropical architecture theories was carried out at Betang Ensaid Panjang. The results of the analysis become the hypothesis that the building applies the principles of humid tropical architecture. Based on PMV and PPD analysis by ASHRAE 55 Standard, it can be identified that the Betang Ensaid Panjang have different levels of thermal comfort in ruai, bilik and tingkak at different times. In the morning it can be identified as slightly cool, in the afternoon and evening, can be identified as slighltly warm and at night, it can be identified as neutral or comfort.
References
Alfred, P. J. (2021). Kajian Arsitektur Tropis Pada Bangunan Rumah Sakit Keluarga Kudus Ende. ALUR : Jurnal Arsitektur, 4(2), 90–97
Anwar, D., Karyono, T. H., & R. Tobing, R. (2021). Kenyamanan Fisik Ruang Pada Permukiman Tradisional Kampung Naga. AGORA:Jurnal Penelitian Dan Karya Ilmiah Arsitektur Usakti, 18(2), 39–45
Hardiman, G. (2012). Pertimbangan Iklim Tropis Lembab Dalam Konsep Arsitektur Bangunan Modern. Jurnal Arsitektur Universitas Bandar Lampung, 2(2), 77–82
Jhonnata, D., Ifadianto, N., & Hardilla, D. (2021). Karakteristik Termal Rumah Suku Dayak di Kalimantan Tengah di TMII ). JURNAL ARSITEKTUR, 11(2), 63–74
Karyono, T. H., & Drajat, A. M. (2016). Arsitektur Tropis : Bentuk, Teknologi, Kenyamanan Dan Penggunaan Energi. Jakarta: Erlangga
Karyono, Tri Harso. (2010). Kenyamanan Termal Dan Penghematan Energi : Teori Dan Realisasi Dalam Desain Arsitektur. Seminar Dan Pelatihan Ikatan Arsitek Indonesia (IAI), March, 1–12.
Kiki, G., Kouchadé, C., Houngan, A., Zannou-Tchoko, S. J., & André, P. (2020). Evaluation of thermal comfort in an office building in the humid tropical climate of Benin. Building and Environment, 185, 1–10.
Kusumowardani, D. (2021). Penerapan Arsitektur Tropis dalam Era New Normal. Jurnal Desain Interior, 6(1), 1.
Noble, A. G. (2007). Traditional Buildings: A Global Survey Of Structural Forms and Cultural Functions. I.B.Tauris & Co Ltd.
Pamungkas, L. S., & Ikaputra, I. (2020). Local Wisdom Arsitektur Tradisional Dan Kenyamanan Termal Tropis. Jurnal Arsitektur ARCADE, 4(2), 160–167.
Rapoport, A. (1969). House Form and Culture (P. L. Wagner (ed.)). Prentice-Hall, inc.
Rosadi, H. E., Rismansyah, N., Fuad, F., & Setiyowati, E. (2012). Pengaruh sudut kemiringan atap bangunan dan orientasinya terhadap kualitas termal. 1, 93–96.
Sardjono, A. B. (2011). Respon Rumah Tradisional Kudus. MODUL Vol.11 No.1 Januari 2011, 11(1), 7–16.
Seran, E. Y., & Mardawani, M. (2020). Kearifan Lokal Rumah Betang Suku Dayak Desa Dalam Perspektif Nilai Filosofi Hidup (Studi Etnografi: Suku Dayak Desa, Desa Ensaid Panjang Kecamatan Kelam Permai). JURNAL PEKAN: Jurnal Pendidikan Kewarganegaraan, 5(1), 28–41.
Tarigan, R. (2019). Membaca Makna Tradisionalitas Pada Arsitektur Rumah Tradisional. Jurnal Arsitektur KOMPOSISI, 12(3), 199–210.
Wang, L., Liu, J., Liu, Y., Wang, Y., & Chen, J. (2011). Study on thermal environment of traditional architecture in tropic climate. Advanced Materials Research, 243–249, 6857–6861.
Wibowo, H. (2021). Meningkatkan Karakter Bangunan Bersejarah & Kenyamanan Visual Dengan Pencahayaan Buatan Studi Kasus: Gedung London Sumatra Indonesia Di Kota Medan. Jurnal Indonesia Sosial Teknologi, 2(3), 377–386.
Zhao, X., Nie, P., Zhu, J., Tong, L., & Liu, Y. (2020). Evaluation of thermal environments for cliff-side cave dwellings in cold region of China. Renewable Energy, 158, 154–166.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
You are free to:
- Share "” copy and redistribute the material in any medium or format
- Adapt "” remix, transform, and build upon the material for any purpose, even commercially
Under the following terms:
- Attribution "” You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions "” You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.
Notices:
- You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation.
- No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.